Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Rev. bras. oftalmol ; 77(4): 214-218, jul.-ago. 2018. tab, graf
Article in English | LILACS | ID: biblio-959101

ABSTRACT

ABSTRACT Objective: We describe the pressure lowering effect of micropulse laser trabeculoplasty (MLT) in patients with uncontrolled open angle glaucoma (OAG). Design: Retrospective case series. Methods: We retrospective reviewed 30 eyes with Open angle Glaucoma (OAG) at the Vista Clinic in Lima, Peru. A single session of MLT treatment was delivered using a 532 nm Frequency doubled Nd. YAG laser to 360º of the trabecular meshwork with a power of 1000 mW, 25 % of duty cycle, and 300 ms. of exposure. The intraocular pressure (IOP) was measured at baseline and at 1 day, 1 week, 3, 6 months post-treatment and were followed up for one last control. Results: The mean baseline IOP was 15.6 mmHg and in the last control was12.8 mmHg, mean follow up time of 19 months (+/- 10 SD). The mean reduction of IOP in the first day was 1.6 mmHg (± 2.6 SD) and 1.2 mmHg (± 3.3 SD) in the last follow up. The mean percentage of IOP reduction was 17.9% and 7 eyes (40%) had IOP reduction greater than 20%. No statistical difference in relation to demographics characteristics of the patients. The greatest reduction was achieved in the first day with a median of 2.00 (P 0.001). A tendency to achieve higher reduction of IOP in patients with higher baseline IOP was found, but was not statistical significant. No adverse reactions occurred. Conclusions: Micropulse laser trabeculoplasty can temporarily be effective in reducing the IOP in some patients with uncontrolled Open angle glaucoma and appears to be safe.


RESUMO Objetivo: Descrevemos o efeito redutor de pressão da trabeculoplastia com laser de micropulso (MLT) em pacientes com glaucoma de ângulo aberto (OAG) descontrolado. Design: Série de casos retrospectiva. Métodos: Foram revisados retrospectivamente 30 olhos com glaucoma de ângulo aberto (OAG) na Clínica Vista em Lima, Peru. Uma única sessão de tratamento com MLT foi administrada usando uma Nd de frequência duplicada de 532 nm. Laser YAG a 360 º da malha trabecular com uma potência de 1000 mW, 25% do ciclo de trabalho e 300 ms. de exposição. A pressão intra-ocular (PIO) foi medida no início e em 1 dia, 1 semana, 3, 6 meses após o tratamento e foram seguidos por um último controle. Resultados: A média da PIO basal foi de 15,6 mmHg e no último controle foi de 12,8 mmHg, com tempo médio de seguimento de 19 meses (+/- 10 DP). A redução média da PIO no primeiro dia foi de 1,6 mmHg (± 2,6 DP) e 1,2 mmHg (± 3,3 DP) no último seguimento. A porcentagem média de redução da PIO foi de 17,9% e 7 olhos (40%) tiveram redução da PIO superior a 20%. Nenhuma diferença estatística em relação às características demográficas dos pacientes. A maior redução foi obtida no primeiro dia com mediana de 2,00 (P 0,001). A tendência de atingir uma redução maior da PIO em pacientes com PIO basal mais alta foi encontrada, mas não foi estatisticamente significativa. Nenhuma reação adversa ocorreu. Conclusões: A trabeculoplastia a laser Micropulse pode ser temporariamente eficaz na redução da PIO em alguns pacientes com glaucoma de ângulo aberto descontrolado e parece ser segura.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Trabeculectomy/methods , Glaucoma, Open-Angle/surgery , Laser Therapy/methods , Peru , Medical Records , Retrospective Studies , Lasers, Semiconductor/therapeutic use , Intraocular Pressure
2.
Radiol. bras ; 49(2): 86-91, Mar.-Apr. 2016. tab, graf
Article in English | LILACS | ID: lil-780938

ABSTRACT

Abstract Objective: To determine whether low-level laser therapy can prevent salivary hypofunction after radiotherapy and chemotherapy in head and neck cancer patients. Materials and Methods: We evaluated 23 head and neck cancer patients, of whom 13 received laser therapy and 10 received clinical care only. An InGaAlP laser was used intra-orally (at 660 nm and 40 mW) at a mean dose of 10.0 J/cm2 and extra-orally (at 780 nm and 15 mW) at a mean dose of 3.7 J/cm2, three times per week, on alternate days. Stimulated and unstimulated sialometry tests were performed before the first radiotherapy and chemotherapy sessions (N0) and at 30 days after the end of treatment (N30). Results: At N30, the mean salivary flow rates were significantly higher among the laser therapy patients than among the patients who received clinical care only, in the stimulated and unstimulated sialometry tests (p = 0.0131 and p = 0.0143, respectively). Conclusion: Low-level laser therapy, administered concomitantly with radiotherapy and chemotherapy, appears to mitigate treatment-induced salivary hypofunction in patients with head and neck cancer.


Resumo Objetivo: Avaliar o impacto do laser de baixa potência na prevenção de hipofluxo salivar em pacientes portadores de câncer de cabeça e pescoço após radioterapia e quimioterapia. Materiais e Métodos: Treze pacientes receberam laserterapia e dez receberam cuidados clínicos. Utilizou-se um InGaAlP laser diodo para aplicação intraoral (comprimento de onda de 660 nm, 40 mW de potência e dose média de 10 J/cm2) e extraoral (comprimento de onda de 780 nm, 15 mW de potência e dose média de 3,7 J/cm2), três vezes por semana, em dias alternados. Sialometrias estimulada e não estimulada foram realizadas antes da primeira sessão de radioterapia e quimioterapia (N0) e 30 dias após o final do tratamento (N30). Resultados: Em N30, os pacientes submetidos à laserterapia apresentaram médias estatisticamente maiores de fluxo salivar estimulado (p = 0,0131) e não estimulado (p = 0,0143), em comparação com os pacientes que receberam apenas cuidados clínicos. Conclusão: A laserterapia de baixa potência realizada concomitantemente a radioterapia e quimioterapia foi capaz de mitigar a hipofunção das glândulas salivares em pacientes portadores de câncer de cabeça e pescoço após o tratamento oncológico.

SELECTION OF CITATIONS
SEARCH DETAIL